Area Monitoring of Shoreline
The mix of VOCs (volatile organic compounds) in the oil changes as it disperses from the source of the spill to the shore. Along the way, benzene and some other volatiles are broken down by sun and seawater. By the time oil reaches the shore, it still contains some VOCs that should be monitored. According to the U.S. government agency Centers for Disease Control, VOCs at the shore can include benzene, toluene, ethylbenzene, xylene, and naphthalene, in varying concentrations and combinations. Some workers in past oil spill clean-up efforts have reported severe headaches, dizziness, nausea and difficulty breathing, which can be associated with coming into contact with spilled oil and oil dispersants.
Recommended RAE Systems Gas Detectors
A handheld photoionization detector such as a MultiRAE Plus or MiniRAE 3000 or ppbRAE 3000 can provide broadband monitoring for VOCs, while an UltraRAE 3000 can be employed to test when benzene is suspected in large quantities in order to determine its concentration. AreaRAE Steel monitors can be deployed individually or in an AreaRAE Network for long-term or short-term monitoring on a stretch of beach or along an established perimeter. They monitor and send their data to a central collection point that consists of a Ruggedized Host Controller laptop computer that is pre-configured with RAE Systems’ monitoring software.
Additional Resources for RAE Systems Gas Detection Solutions
Applications Notes
Technical Notes
- TN-106 - Correction Factors, Ionization Energies, and Calibration
Characteristics - TN-118 - Using RAE Systems PIDs for Measuring Soil Headspace and in Soil Vapor
Extractions - TN-136 - UltraRAE and UltraRAE 3000 Operation Tips
- TN-165 - Combating Drift in Portable and Fixed PIDs
- TN-178 - Humidity Filtering II Tube for PID Measurements in Humid Environments
Resources from U.S. Government Agencies
Links to helpful external resources. These are external sites and RAE Systems has no control over their content.
Recommended Products
Part numbers for Recommended RAE Systems Gas Detectors
MultiRAE Plus
- 009-3121-010 (unit only)
- 009-3121-014 (unit with accessory kit and calibration gas kit)
- Call for other configurations
UltraRAE 3000
- 059-D310-000 (unit only)
- 059-D311-200 (unit with accessory kit and calibration gas kit)
- 600-0063-000 (Replacement benzene calibration cylinder)
- 012-3022-010 (RAE Sep Benzene Tubes)
- Call for other configurations
Colorimetric Hand Pump Kit
- LP-1200 (unit only)
Colorimetric Tubes
- 10-101-01 (Benzene 0.5 – 10 ppm)
- 10-101-10 (Benzene 5 – 40 ppm)
- 10-101-20 (Benzene 5 – 100 ppm)
- 10-110-30 (Hydrocarbons 50 – 1000 ppm)
- 10-114-20 (Toluene 10 – 300 ppm)
- 10-112-20 (Xylene 10 – 200 ppm)
MiniRAE 3000
- 059-B110-000 (unit only)
- 059-B111-100 (unit with accessory kit and calibration gas kit)
- 600-0002-000 (Replacement isobutylene calibration cylinder)
- Call for other configurations
ppbRAE 3000
- 059-C110-000 (unit only)
- 059-C111-100 (unit with accessory kit and calibration gas kit)
- 600-0069-000 (Replacement isobutylene calibration cylinder)
- Call for other configurations
MiniRAE Lite
- 059-A100-000 (unit only)
- 059-A110-100 (unit with accessory kit and calibration gas kit)
- 600-0002-000 (Replacement calibration cylinder)
- Call for other configurations
AreaRAE Steel, AreaRAE Network and Ruggedized Host Controller
- Call for review of your application